GEO-LOG 3 Pressio Module proposes a help to the L. MENARD pressuremeter test
evaluation according
to the NF P94-110-1 standard. It consists to display, under
graphic representation, the final result achieved by the normalized
calculation. So the expert can check immediately if the test evaluation
needs a consistent analysis of the evaluation stages. |
|

|
Functions : |
|
|
-
Permanent access to the raw and corrected data
in a spreadsheet (pressure,
volume).
- Control of the intermediary calculations like the determination of the
pseudo-elastic range and display of the regression straight
lines (LP) ...
|
|
|
- Graphic modification of the intermediary variables based on the curves
(P1,V1 P2,V2), or directly on their numerical values in the
display/acquisition zones, when the expert thinks that the test
conditions don't enable an automatic evaluation according to
the standard. In this case, the expert interpretation is clearly
distinguished from the automatic evaluation on the final report
by the addition of a remark on the modified results.
- Printing of a
minute report (NF-P94-110-1
standard) for each pressuremeter test.
- Printing of a synthetic report (graphical and numerical report)
for the results of each test evaluation regarding a pressiometric
boring.
- An automatic evaluation of each drilling test, without curves display, directly
under a list of numerical results, can be chosen.
|
|
|
|
- Import of pressuremeter data automatically acquired by a
measurement device, under textual format files.
- Storage in the GEO-LOG 3 geotechnical database.
Once the evaluation
completed, the pressiometric values (Em, Pf*, Pl*, Sigma HS module)
are automatically stored in the database and can be processed
by GEO-LOG 3
- Printing of a log in the GEO-LOG
3 principal manager
in which the result of the pressiometric test can be completed
by the lithological data, drilling parameters, well completion,...
which have been acquired. Different presentation options enable
to valorize the results (colours, symbols, graduation axis,
grids, ...).
|
|
|
|
- Tests archival storage in archive file (ag3) independent of the database.
- Export of data under Textual files, Microsoft Excel, ...
|

|
New options compared with Pressiomig
1.0 : |
|
|
- NF P94-110-1 European standard integration (January 2000)):
Acquisition
of the Volume
at 1 s.
- Resistance
test suited to the device : CalP calculation with V=700 cm3 or 550 cm3.
- Calculation
of the Limit pressure :
hyperbolical extrapolation method.
- New graphics
- Dynamic
design of curves (they are no longer stored in the database
like in the former version).
- Plot
of the P1V1, P2V2, LP, CP positions and of the interpretation
curves (regression straight lines for the CP calculation,
extrapolation curves for the LP calculation).
- New reports
Minute
report according
to the NF P 94-110-1 standard.
- Synthetic
report completed
by the columns N° level, Vr (V60 not corrected), the
calculation method chosen for LP.
- Printing
options for reports : choice of margins, header-footer (synthetic
report), optional display of the data spreadsheet, specific
points (P1V1, P2V2, PF) and interpretative curves.
- Complete
report of the evaluation : complete
evaluation form of the boring and printing of this one.
- Calibration extension (Resistance test suited to the probe) :
- Addition of the resistance test suited to membranes
- Reference
at the level of each test.
- Calculation
of the mP limit
conventional resistance from the curve V60=f(P).
- Modification of the correction due to the hydraulic
load
- Distinction
of aquatic
sites by
acquiring the depth at the bottom of water (boring form).
- New fields for the pressiometric depth table
Data
: Level and Creep columns
.
- Preservation
of the evaluation options : Select P1P2, Select Em, Select CP, Select LP,
calculation method for LP, intermediary results (LevelP1,
LevelP2, CP, LP, CP/LP, LiP, LhP, LxP).
- Graphic
: Separated
display of the pressiometric curve, the creep curve or both
curves. Display of the pressiometric curve with no
- corrected
data. Display of the calibration curve in the test pressiometric
curve.
- Information
: K0 (Coefficient
of pressure for ground at rest), Total volumic mass of the
ground, Resistance suited to the membrane, Operator, Recorder
(Measurement equipment).
- Additional
fields for the Probe
table : Split
tube, cell type.
|
|
Hardware configuration required
:
|
Minimum : |
- PC with a microprocessor Pentium® 75 or more.
- Windows® 95 and Windows NT®
3.51 Service Pack 5 and successors (does not work with previous
versions).
- With
Windows® 95, 32 Mb of RAM are required
to run the program alone. 64 Mb are required for Windows NT® Workstation. A higher memory
can be necessary to run simultaneously several GEO-LOG 3 applications.
- 40 Mb space disk available.
- CD-ROM.
- SVGA or higher resolution
(800x600 display minimum).
- Microsoft mouse or equivalent
(with 2 buttons).
|
Recommanded
: |
- PC with Pentium® III 500 MHz or more.
- With
Windows® 95, 98, Me, NT® 4, 128 Mb of RAM or more.
With
Windows® 2000, XP, 256 Mb of RAM or more.
- 1024x768 display, 65536
colours (High color).
- Printers used to test
the software with Windows 95/98 standard drivers:
* Black
& White: HP LaserJet III, HP LaserJet 4P, HP LaserJet 6L,
HP Deskjet 500, Toshiba DP2570.
* Colour : HHP PaintJet XL 300 (A3, A4),
HP Deskjet 500 C, HP Deskjet 1120C (A3, A4), Epson Stylus Color 440,
Epson Stylus Photo 700.
|